MC-KT-Series metal clad and with draw able panels are designed & manufactured by KTC company, according to IEC-60298 standards. This series of MV panels meets all requirements for safety, reliability and maintainability that made it as one of the most well known panels in electrical medium voltage switchboards.
some of the main advantages of MC-KTC series are:
- Op
timum safety for operators

Operation reliability
- Low maintenance construction and apparatus
- Supporting different type of circuit breakers and contactors

Type tested in ABB and PT&T Laboratories
With draw able part of this panel is lighter than other similar types and could be installed in any kind of buildings without any need for flat floor. In addition, this part provides complete safety for maintenance & repair staff. With this with draw able part, interlocking system can for, there is no need for a flat floor for moving in/out the With draw able part. One track is provided for a set of switchgear which is designed based on the requirements of the industry
and easy removal.
Type MC-KT switchgear provides both external and internal protection.

External protection which is:
Complete enclosure of the panels.

Internal protection which is provided by:
Inserted metal compartmentalization with enforced-operation shutters. (optional arc-resistant)
Electrical Data:

 

MC-KT-Series (ZS Model) Dimensions are as mentioned in the following drawings :

 

Easy maintenance & maximum safety
In this panel, there is no needed to open the door for issuing open/close commands, moving
the withdraw able part, opening / closing the earthing switch. Also insure maximum safety for
personnel, panel is prevents aginst wrong maneuver (according to VDE 0105-part 1 st. )
Interlocking system is designed to provide the following advantages:
- At the time of moving withdraw able part from test condition to operation condition, the door of the panel always can be remained closed.

- At the time of closing ear thing switch, circuit breaker shall be opened and with draw able part shall be in test position.

- During racking-out of with draw able part, circuit breaker shall be opened.

When ear thing switch is closed, with draw able part can not be put into service position and closing command to C.B can not be issued.
Ear thing handle that opens & closes the ear thing switch can be placed in its proper position only when all interlock conditions are met. A handle which only could be placed in its position if all interlock conditions are satisfied, will do the draw out mechanism part.

 

 

 

 

 

 







 

 

 